Selection of the desired Preset is controlled on the Array’s control panel by the three push buttons
located directly below the digital readout. The Preset Up and Preset Down buttons are used to select
the desired Preset and the Enter button used to enter the selection into the DSP.
The readout display will ash while the selected Preset’s conguration settings are being entered into
the DSP and return to a steady glow when the procedure is complete. If by accident you select an
empty Preset, the dots following the numbers will ash as an indication no Preset is available. In mul-
tiple module arrays, the Preset Up, Preset Down and Enter buttons are disabled in the “Slave” modules
(the upper modules)
Note that the Digital readout will also display the array’s level setting in dB when the array’s Volume Up
and Down buttons are being used to adjust the array’s output level.
Presets can also be loaded using RHAON. The Beams / Presets tabs opening window lists and describes the Presets stored in the Array’s
memory and highlights the one installed. In the example shown below, Preset 12 is installed. If no Preset was installed a separate listing
would be added for it.
Notice that each listing includes a description of the Preset and coded information on the Beams and the DSP status. In the Beams
listing, the rst number set shows the acoustic center location, the 2nd set the number of beams, the third the aiming angle, the 4th the
opening angle and the nal number the amount of attenuation assigned to the beam. The DSP? column shows whether or not the Preset
includes DSP data (EQ settings for example).
Selecting one of the Presets and pressing the Load Preset button will load the selected Preset into the Array’s working memory. If no
DSP data is included in the Preset, a dialog box will call the lack of DSP data to your attention and ask if it is OK to proceed.
Answering Yes, will initiate the process, introduce a Loading Status screen and hide the lettering in the Beams / Presets window. The Load-
ing Status window will disappear and the lettering will reappear when the process is complete.
34