SUPERVISE
The dark grey section on the left includes the loudspeaker’s input and output monitoring facilities, identication elds, and basic operating
controls: Power On/Standby, the Wink Light toggle, Wink with Audio, Input Gain, Polarity Invert, and Mute. Any or all of these controls may
be restricted to authorized operators and subject to password-protected access.
The loudspeaker icons on the right each have “trafc light” status indicators; green is for all OK and red is for driver failure. Yellow indicates
the driver has repeatedly been driven far enough into limiting that its normal life span may have been reduced. The trafc light conditions
are mirrored in the status eld of the supervise icons. Driver conditions are dynamically supervised with program material but an additional
test button can conrm coil status. The use of these manual test buttons is required in case the program material either lacks specic
frequencies or is too weak.
Notice that all of the drivers in the array are being monitored and that each Array module has its own Wink light. During setup this allows
you to easily identify each array module and verify that its address number switches are properly set. If you press the Wink light for the top
module and the wink light on the middle module comes on, you know the switches are set wrong.
The loudspeaker’s RHAON Microcontroller and DSP and microprocessor Firmware version numbers are shown in a darker grey panel at
the bottom right of this window.
The panel at the bottom displays the status of the Voltage Detect (Fault Monitoring) and Fault Relay circuits, the Priority Override function
and the Ethernet inputs.
The Priority Override indicator will change from showing “Inactive” to “Active” when the override circuit is in use (has been activated).
The Fault Relay status line will change from “Off” to “On” when an amplier fault has been detected or the Ethernet carrier signal is lost.
The Voltage Detect will read “High” when it senses a voltage on the Sense input line and “Unknown when no voltage is present.
The Ethernet Status will show “Primary” when an Ethernet Carrier signal is detected at the Primary Ethernet input and “Off Line” if the car-
rier signal is lost, except in “Redundant” systems having a secondary Ethernet source. In these systems, the amplier will be switched over
to the secondary input as soon as the primary signal is lost; the status line will then change to “Secondary”.
Users Manual IC