APPENDIX I: Audio Evacuation & Life Safety Functions
Although not certied as a “Life Safety” system, RHAON has been designed to meet the stringent requirements of most Audio Evacuation /
Life Safety system specications.
Since “Life Safety” requirements vary widely from country to country and from one locality to another, we strongly recommend you contact
your local authorities for an opinion before proposing a RHAON system for any Life Safety application. They know best what’s required in
your area to meet code requirements.
A summary of RHAON’s life safety features follows.
Redundant CobraNet Inputs
All RHAON Empowered ampliers have a secondary Ethernet input that can be used to provide a “redundant” control and distribution sys-
tem. Such systems, of course, also require a redundant Ethernet system. Changeover to the secondary or redundant system is automatic
in the event the primary system fails.
Continuous Performance Monitoring
The performance of all RHAON Empowered Ampliers and Loudspeakers is constantly monitored for faults and abnormalities.
Event Logging and Notication
Pre-selected events are recorded in a Log le for later review and analysis; may be automatically forwarded via e-mail to another location.
Fault Monitoring
An opto-isolated input monitors the integrity of an external wiring loop by detecting the presence of a “sense” voltage and reporting its
absence via the Ethernet network.
Fault Relay
An isolated relay uses external wiring to report any amplier fault, the loss of the Ethernet carrier signal or the absence of a sense voltage
to associated monitoring equipment. Normally Open & Normally Closed contacts handle up to .5 Amp @ 28 Volts AC or DC. The detection
circuit functions either with or without the array being connected to a RHAON network. If the RHAON carrier is present when the array is
rst turned on, it reports if the carrier signal is lost; if the carrier isn’t present when the array is turned on it won’t report unless the carrier
signal suddenly appears.